nfc-pcsc's pcsclite binding does not fail when pcscd is not running — it
retries SCardEstablishContext in a tight loop on the calling thread, which
here is Electron's main thread. ~12k stat()s a second on
/run/pcscd/pcscd.comm, event loop dead: the window never paints, the
renderer is never reaped, and the watchdog can't fire because it needs the
same event loop. The douro sat like that for 11 hours at 80% CPU (its
CPUQuota ceiling), ignoring SIGTERM, with nothing in the journal after
[StateStore].
Check the socket exists before touching the binding. This is what makes
the "best-effort, every failure swallowed into a status callback" contract
in the module header true, and it also covers pcscd dying at runtime on a
machine that does have a reader.
The Feitian R502-CL (and cheap CCID readers generally) can wedge: it keeps
detecting a card but every APDU returns "card absent or mute", and ONLY a
USB power-cycle clears it — restarting pcscd or the app does not (confirmed
on-device). Until now that left cash-out/cash-in taps dead until a manual
replug.
- nfc-service.ts: count consecutive read failures; after 3 (gated by a 30s
cooldown so a still-wedged reader can't reset-loop) trigger
nfc-reader-reset.service. nfc-pcsc then re-detects the reader on USB
hotplug with no app restart (verified live).
- batm3.nix: nfc-reader-reset.service (oneshot, root) re-binds the reader's
USB device (a software replug); reader-agnostic via the CCID interface
class (0x0B) so it also covers a future ACR1252U. A polkit rule lets the
unprivileged `bitspire` app start just that one unit.
Hardware track (separate): the durable fix is a better reader (ACR1252U —
large antenna for behind-panel, firmware-upgradable). This change makes any
reader's wedge a ~2s self-heal in the meantime.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Hammering a flaky CCID reader with rapid re-reads wedges it into a
present↔empty storm (only a USB replug clears it). After a failed read,
ignore card re-detections for 1.5s; successful reads don't cool down.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Retrying a read hammered the cheap CCID reader into a stuck present↔empty
loop (only cleared by a reboot), so drop the retry: a read is a single
attempt and the user re-taps if the RF link drops mid-read. Also skip the
Capability-Container round-trip in the common case — NTAG424 Bolt Cards use
NDEF FileID E104, so try E104/0004 directly and only read the CC to discover
the id if both fail. Fewer APDUs → a read completes inside a shorter stable
window.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
First real-card tap read the NDEF file with id 0004 and got "not a Bolt
Card" — NTAG424 (Bolt Cards) use FileID E104. Read the Capability Container
(EF E103) after selecting the NDEF app to learn the advertised NDEF FileID,
then read that file; fall back to E104/0004. Tolerates a transient transmit
error (surfaced as a retryable status; the next tap re-reads).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Main-process driver over nfc-pcsc (PC/SC). On tap it reads the NTAG424
Type-4 NDEF file via ISO7816 APDUs (select NDEF app D2760000850101 →
select file → ReadBinary NLEN + message) and extracts the lnurlw voucher
(fresh SUN p/c per tap), forwarding it to the renderer on `nfc:card-tapped`
(+ `nfc:status`). Lazy, guarded import — a missing reader/pcscd just
reports 'unavailable', never breaking the cash-out QR path. Preload
removeAllListeners guards against a double payment-trigger on renderer reload.
- electron/nfc-service.ts: startNfcReader() + readNdefLnurlw()/extractLnurlw().
- electron/nfc-service.test.ts: 7 tests (NDEF URI extraction, Type-4 read
sequence incl. AID select, empty-file + select-fail handling).
- main.ts start + IPC forward; preload + electron.d.ts listeners.
- add nfc-pcsc dep (native @pokusew/pcsclite; nix build handling next).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>