Add circuit breaker location floor plans
- Add photos showing circuit breaker locations for each floor: - RDC (ground floor) - 1st floor (French) / 2nd floor (US) - 2nd floor (French) / 3rd floor (US) - Add prominent callout explaining French floor numbering convention - Organize images in infrastructure/images/ 🤖 Generated with [Claude Code](https://claude.com/claude-code) Co-Authored-By: Claude Opus 4.5 <noreply@anthropic.com>
This commit is contained in:
parent
9302fc2e2e
commit
86f0d4ba34
4 changed files with 32 additions and 13 deletions
|
|
@ -9,15 +9,41 @@ tags:
|
|||
|
||||
# Electrical & Circuit Breakers
|
||||
|
||||
## Main Electrical Panel
|
||||
> [!info] French Floor Numbering
|
||||
> In France, floors are numbered differently than in the US/UK:
|
||||
> | French | American/UK |
|
||||
> |--------|-------------|
|
||||
> | **RDC** (Rez-de-chaussée) | Ground Floor / 1st Floor |
|
||||
> | **1er étage** (1st floor) | 2nd Floor |
|
||||
> | **2ème étage** (2nd floor) | 3rd Floor |
|
||||
>
|
||||
> The floor plans and labels below use **French numbering**.
|
||||
|
||||
## Circuit Breaker Locations
|
||||
|
||||
Each floor has its own circuit breaker panel. See floor plans below for exact locations.
|
||||
|
||||
### RDC (Ground Floor)
|
||||
|
||||
![[rdc-circuit-breakers.png]]
|
||||
|
||||
### 1er Étage (1st Floor - US: 2nd Floor)
|
||||
|
||||
![[1st-floor-circuit-breaker.png]]
|
||||
|
||||
### 2ème Étage (2nd Floor - US: 3rd Floor)
|
||||
|
||||
![[2nd-floor-circuit-breaker.png]]
|
||||
|
||||
---
|
||||
|
||||
## Circuit Panel Details
|
||||
|
||||
### Main Electrical Panel
|
||||
|
||||
- **Location:** *TBD*
|
||||
- **Access:** *TBD (describe how to access - door, cabinet, etc.)*
|
||||
|
||||
### Panel Layout
|
||||
|
||||
*TBD: Add photo or diagram of panel*
|
||||
|
||||
| Breaker # | Amperage | Serves |
|
||||
|-----------|----------|--------|
|
||||
| Main | *TBD* | Whole property |
|
||||
|
|
@ -26,16 +52,9 @@ tags:
|
|||
| 3 | *TBD* | *TBD* |
|
||||
| ... | ... | ... |
|
||||
|
||||
## Secondary Panels (if any)
|
||||
|
||||
### Panel 2
|
||||
|
||||
- **Location:** *TBD*
|
||||
- **Serves:** *TBD*
|
||||
|
||||
## How to Reset a Tripped Breaker
|
||||
|
||||
1. Locate the panel
|
||||
1. Locate the panel for your floor (see floor plans above)
|
||||
2. Find the tripped breaker (will be in middle position or show red)
|
||||
3. Push breaker firmly to OFF position
|
||||
4. Push breaker to ON position
|
||||
|
|
|
|||